Table 1 Disinfection effect on stainless steel carriers surface by 222-nm UVC excimer lamp (temperature of the carriers was 20 °C; bacterial suspensions were prepared in PBS)

From: Study on disinfection effect of a 222-nm UVC excimer lamp on object surface

Diluent for bacterial suspension; treatment for stainless steel carriers

Mean log10 CFU in positive control group (range)

Mean KL ± SD for different irradiation time (s)

15

30

60

PBS; not dried

5.95 (5.90–5.99)

Staphylococcus aureus

3.05 ± 0.03

3.40 ± 0.05

4.06 ± 0.06

5.91 (5.84–5.96)

Escherichia coli

3.10 ± 0.02

3.49 ± 0.03

4.18 ± 0.06

5.87 (5.81–5.93)

Pseudomonas aeruginosa

3.09 ± 0.02

3.53 ± 0.01

4.18 ± 0.13

PBS; dried

6.02 (5.98–6.05)

Staphylococcus aureus

2.95 ± 0.01

3.21 ± 0.04

3.45 ± 0.07

5.99 (5.95–6.03)

Escherichia coli

2.97 ± 0.01

3.25 ± 0.04

3.49 ± 0.05

5.96 (5.90–6.03)

Pseudomonas aeruginosa

2.93 ± 0.01

3.20 ± 0.04

3.41 ± 0.05

  1. SD standard deviation