Skip to main content
Fig. 1 | AMB Express

Fig. 1

From: Development of a standardized method to evaluate the protective efficiency of cosmetic packaging against microbial contamination

Fig. 1

Illustration of the contamination procedure developed to reproduce natural contamination due to skin contact under standardized conditions. For flexible packaging (a), the nozzle of the pack is pressed in contact with the contaminated compress (106 CFU/mL) (1) and the dose (as defined by the provider) is released (2). When it is completely restituted (3), the pressure on the packaging is relieved and the movement is prolonged for a distance of 2 cm (4) to mimic manual wiping of the tip. This procedure can be adapted to rigid packaging (b) by replacing the pressure on the side of the pack by actuation of the delivery pump

Back to article page