Skip to main content

Table 3 Results of the experimental runs based on the central composite design

From: Modeling photocatalytic degradation of diazinon from aqueous solutions and effluent toxicity risk assessment using Escherichia coli LMG 15862

Run

A:PH

B:Contact time (min)

C:Concentration of diazinon (mg/L)

D:Dosage of nanoparticles (mg/L)

Removal efficiency (%)

Predicted value

1

7.500

65.00

20.50

550.0

88.90

89.26

2

7.500

65.00

20.50

550.0

88.68

89.26

3

7.500

65.00

20.50

550.0

87.99

89.26

4

7.500

65.00

20.50

550.0

88.39

89.26

5

7.500

65.00

20.50

550.0

90.91

89.26

6

7.500

65.00

20.50

550.0

90.70

89.26

7

5.250

37.50

10.75

325.0

83.60

83.67

8

9.750

37.50

10.75

325.0

77.24

76.92

9

5.250

92.50

10.75

325.0

84.10

85.02

10

9.750

92.50

10.75

325.0

77.33

77.19

11

5.250

37.50

30.25

325.0

76.30

76.86

12

9.750

37.50

30.25

325.0

70.10

69.36

13

5.250

92.50

30.25

325.0

81.17

79.52

14

9.750

92.50

30.25

325.0

71.23

70.93

15

5.250

37.50

10.75

775.0

90.00

90.52

16

9.750

37.50

10.75

775.0

84.00

84.99

17

5.250

92.50

10.75

775.0

90.20

90.28

18

9.750

92.50

10.75

775.0

84.00

83.66

19

5.250

37.50

30.25

775.0

83.00

82.47

20

9.750

37.50

30.25

775.0

76.90

76.20

21

5.250

92.50

30.25

775.0

83.00

83.54

22

9.750

92.50

30.25

775.0

76.91

76.18

23

3.000

65.00

20.50

550.0

78.81

78.33

24

12.00

65.00

20.50

550.0

63.30

64.22

25

7.500

10.00

20.50

550.0

78.39

78.25

26

7.500

65.00

20.50

550.0

79.00

79.59

27

7.500

65.00

1.000

550.0

96.06

94.95

28

7.500

65.00

40.00

550.0

79.10

80.66

29

7.500

65.00

20.50

100.0

77.20

77.78

30

7.500

65.00

20.50

1000

90.00

89.87